DVS 510 Series • Remote Configuration and Control

80

Starting the Software

1.

Click

Start

>

Programs

>

Extron

Electronics

>

Signal

Processing

>

Signal

Processing

Products

Control

Program

.

Alternatively, if an SPPCP icon was installed on the desktop, double-click the icon. The
Select Connection Type window appears.

2.

Select either the

TCP/IP

tab for an IP connection or the

RS232

tab for a serial

connection.

•

For an IP connection:

•

In the

IP

Address/Host

Name

field, either enter the IP address of your DVS or

select the address from the menu.

NOTE: 192.168.254.254 is the factory-specified default IP address.

•

If you are using a port other than the default port 23, enter the port number in
the

Telnet

Port

field.

•

If the unit is password protected, enter the appropriate administrator or user
password in the

Password

field.

•

For a comm (serial) connection:

•

Select the COM port from the

Port

menu.

•

Select the transmission rate from the

Baud

Rate

menu.

Figure 34.

Tabs on the SPPCP: Select Connection Type Window

3.

Click

Connect

. The Signal Processing Products Control Program main window opens

(see

figure 35

on the next page), and the software is ready for operation.