Cabling and features, Power input — external, Power input — internal – Extron Electronics IPCP Pro Series Setup Guide User Manual

Page 5: Power output — switched 12 vdc power output, Ocessor (see, Attention

Advertising
background image

5

Cabling and Features

Attach cables using the following wiring diagrams as a guide. Full details are available in the IPCP Pro Series User Guide.

ATTENTION:

Installation and service mus t be performed by experienced personnel.

ATTENTION:

L’installation et l’entretien doivent être effectués par du personnel expérimenté.

Power Input — External

POWER

12V

x.xA MAX

R

Ground
all devices.

External

Power Supply

(12 VDC, 1 A max.)

– Return

+12 VDC input

Ridged

Smooth

1A MA

X

100-240V 50-60Hz

Power Input, External Power Supply

• Front panel LED ( ) blinks during

boot-up and lights when the IPCP

is powered and operational.

• Connect to

included 12 VDC

power supply.

Rear

Panel

Front Panel

NOTE:

Check the polarity of

the power supply before
connecting it to the IPCP.

Ridged

Smooth

Tie Wrap

3/16"

(5 mm)

Max.

Power Input — Internal

R

1.2A MAX

100-240V 50-60Hz

Power Input, Internal Power Supply

• Front panel LED ( ) blinks

during boot-up and lights

when the IPCP receives power.

• Connect to 100 to

240 VAC.

Rear Panel

Front Panel

Power Output — Switched 12 VDC Power Output

2

1

LIMIT

SWITCHED

12 VDC

OVER

4

3

12 VDC

SWITCHED 12 VDC

40W MAX TOTAL

3

4

1

2

Lights if total power draw

is

44-48 watts.

Lights if total power draw

exceeds

48 watts.

Power output shuts off for

a period to allow the user

to correct the overload.

Switched 12 VDC

Power Output

• 12 VDC, 40 watts (max.)

= total output for all four ports

combined

• Corresponding front panel

green LEDs ( ) light when

power is available at each port.

3/16"

(5 mm)

Max.

Rear
Panel

Front
Panel

Tie Wrap

ATTENTION:

Always use a power supply
supplied or specified by Extron.
Use of an unauthorized power
supply voids all regulatory
compliance certification and
may cause damage to the
supply and the unit.

ATTENTION:

Utilisez toujours une source
d’alimentation fournie par Extron.
L’utilisation d’une source
d’alimentation non autorisée
annule toute conformité
réglementaire et peut
endommager la source
d’alimentation ainsi que l’unité.