Troubleshooting
Under different circumstances, the front panel LED lights green or amber, which provides
diagnostic information.
Amplifier Fails to Exit Standby Mode Promptly
Power LED
Color
Problem Description
Problem Solution
Amber
No output signal.
•
No input detected: verify that there is an
input signal.
If a signal is present, raise the input level.
•
The amplifier is in standby mode and the
output has been turned off. Check the
remote port.
Green or
Amber
Slow to exit standby
mode when a signal is
present.
•
The input signal may be too weak. Raise
the input level.
Amplifier Enters Standby Mode Too Early
Power LED
Color
Problem Description
Problem Solution
Green or
Amber
Enters standby mode
early.
•
The input signal may be too weak. Raise
the input level.
MPA 401-70V and MPA 401-100V • Setup and Operation