X1!
= Input selection
1
= Mic 1
2
= Mic 2
3
= Line 3
X1@
= Output selection
1
= Variable
2
= Fixed
X1#
= Version number
Listed to two decimal places (for example, x.xx)
X1$
= Version and Build number
The least significant bits is the build number (for example, x.xx.xxxx)
X2@
= Internal temperature
Degrees Celsius
X2$
= Verbose/Response mode
0
= Tag OFF, Broadcast OFF (no tag in GET command response, always tag in
SET command response)
1
= Tag OFF, Broadcast ON (not tagged, broadcast)
2
= Tag ON, Broadcast OFF
3
= Tag ON, Broadcast ON
Default = 1
NOTE:
If ‘tagged responses’ is enabled, all read commands will return
the constant string + the data, similar to setting the value, for
example,
command:
E
CN
}
response:
Ipn
•X1@]
X3$
= Baud rate
0
= 9600
1
= 19200
2
= 38400 (default)
3
= 115200