Setting JMP2 and JMP3 to Positive Vertical and/or Horizontal Sync Polarity
Horizontal and vertical sync polarity can be set by configuring the internal jumpers on the 
MTP/HDMI U R main board. The default setting is negative sync (H- V-), and can be changed 
by resetting the position of the jumpers as follows:
1.
If the unit is not already open, follow steps 1 and 2 in the “
2.
Locate JMP2 and JMP3 on the main board. Remove and reposition the jumper block 
over both pins (see figure below). Repeat as desired for the second jumper. 
Reposition the jumper 
block to cover both pins.
Figure 14.
Inverting Sync with Jumpers JMP2 and JMP3
3.
Replace the top cover and follow steps 4 and 5 in the“
” section.
To reset the syncs to default, open the unit and place the applicable jumper block to cover 
only a single pin.