Simple instruction set™ control, Host-to-interface communications, Symbol definitions – Extron Electronics MTP SW6 User Guide User Manual
Page 24: Simple instruction set, Control, Simple instruction set control

Simple Instruction Set
™
Control
Host-to-Interface Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
unit executes the command and sends a response to the host device. All responses from
the unit to the host end with a carriage return and a line feed (CR/LF = ]), which signals
the end of the response character string. A string is one or more characters.
Symbol Definitions
Symbols (variables), defined on the next page, are used throughout the
Command/Response Table for SIS Commands
. The symbols
represent variables in the unit-initiated messages and the command/response table fields.
]
= CR/LF (carriage return/line feed)
}
= Carriage return (no line feed)
•
=
Space (hard) character
X!
= Input
1 – 6
X@
= Threshold
0 = outside of threshold range
1 = within threshold
X#
= Input peaking range
00 – 65
X$
= Input level range
00 – 255
X%
= Skew adjustment range
00 – 31 (each step = 2ns)
X^
= Video plane
0 = red
1 = green
2 = blue
X&
= RS-232 insert status
0 = disabled
1 = enabled
X*
= Audio/RS-232 wire pair input type
0 = audio
1 = RS-232
X(
= Audio gain
0 – 24 (1 dB/step)
X1)
= Numeric dB value
–18 to +24 (45 steps of gain or
attenuation) (Default = 0 dB)
X1!
= Audio attenuation
1 – 18 (1 dB/step)
X1@
= Volume adjustment range
0 – 100
X1#
= Mute, Front panel lock
0 = off
1 = on
X1$
= Switch mode
1 = normal (manual)
2 = auto
X1%
= Firmware version
v.vv
MTP SW6 • Remote Control
20