Command/Response Table for SIS Commands (continued)

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Audio/RS-232 TP input (wire pair 3 and 6) configuration

NOTE: The RS-232 output insert ports, when enabled (

EX%

*1Lrpt

}

), override the audio/RS-232 TP input configurations.

Configure input as audio

X#

*Ø\

Typ

X#

*Ø

]

Define the audio/RS-232 input as audio, such
as provided by an MTP 15HD A transmitter.

Configure input as RS-232

X#

*1\

Typ

X#

*1

]

Define the audio/RS-232 input as serial
communications, such as provided by an
MTP 15HD RS transmitter.

Read TP input configuration

X#

\

X$]

Show the audio/RS-232 wire pair input
definition.

RS-232 output inserts and UART port enable

Enable an RS-232 output
insert port

EX%

*1Lrpt

}

Lrpt

X%

*1

]

Enable the RS-232 insert on the

X%

output.

This disables the UART port.

Enable a UART port

EX@

*2Lrpt

}

Lrpt

X%

*2

]

Enable the UART port on the

X@

output. This

disables the RS-232 output insert.

Enable the input on the
output (disable both the
RS-232 output insert and
any UART port)

EX@

*ØLrpt

}

Lrpt

X%

*Ø

]

Default condition. Disable the RS-232 insert
and UART port on the

X@

output. The switcher

passes the audio or RS-232 on wire pair 3 and
6 of the tied input.

Enable or disable all ports

EX^

*Lrpt

}

LrptØØ*

X@]

Enable or disable all RS-232 ports or UARTs

Read the RS-232 output
insert and UART port status

EX@

Lrpt

}

X^]

Show the status of the RS-232 output insert
port and the UART port.

Input signal level and peaking and auto calibrating

Set input signal peaking

EX#

*

X&

Ipek

}

Ipek

X#

*

X&]

Set a specific pre-peak level for the TP input.

Increment input peaking

EX#

+Ipek

}

Ipek

X#

*

X&]

Increase the input pre-peaking level by 1.

Decrement input peaking

EX#

-Ipek

}

Ipek

X#

*

X&]

Decrease the pre-peaking level by 1.

Read input peaking setting

EX#

Ipek

}

X&]

Execute auto calibration

EX#

*ØAADJ

}

Aadj

X#

*2

]

{start}

Qik

]

{tie creation}

Aadj

X#

*

X*]

{finished}

Ipek

X#

*

X&]

{new value}

Tie input

X#

to output 1 and auto adjust the

peaking on input

X#

. The

X*

value in the

response reports whether the adjustment
value was within or outside of the threshold.

Iseq

X#

*

X(

*

X(

*

X(]

{new value}

NOTES: • Before issuing the auto calibration command:

1.

Disconnect the power and RJ-45 cables at the MTP transmitter connected
to

X#

.

2.

Connect the cables removed in step 1 to the included MTP signal generator.

3.

If the input cable is longer than 200 feet (60 m), place the Pre-Peak switch
on the MTP signal generator to on (up when the RJ-45 connector on the
signal generator is to the right as shown at right). If the cable is shorter
than 200 feet (60 m), place the switch down.

• The MTP signal generator does not work on cable lengths over 400 feet

(120 m). Set the level and peaking to its maximum value of 255.

Pre-Peak
is on

NOTE:

X@

= Output number

01 – (maximum number of outputs for your matrix size)

X#

= TP input number

01 – (maximum number of TP inputs for your matrix size)

X$

= Audio / RS-232 wire pair input type

0 = audio

1 = RS-232

X%

= RS-232 output insert port number

01 – 16

X^

= RS-232 output insert status or port

0 = disabled

1 = RS-232 enabled

2 = UART enabled

X&

= Input level and peaking range

000 – 255

X*

= Threshold

0 = outside of threshold

1 = within threshold

X(

= Skew adjustment range

00 – 31 (each step = 2 ns)

MTPX Plus 6400 Series Matrix Switchers • Programming Guide

73

Advertising