SW4 3G HD-SDI • Installation and Operation

2-3

3

. Mechanical loading — Mount the equipment in the rack

so that a hazardous condition is not achieved due to

uneven mechanical loading.

4

. Circuit overloading — Connect the equipment to

the supply circuit and consider the effect that circuit

overloading might have on overcurrent protection and

supply wiring. Consider equipment nameplate ratings

when addressing this concern.

5

. Reliable earthing (grounding) — Maintain reliable

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct

connections to the branch circuit (e.g., use of power strips).

Rack mounting instructions

For optional rack mounting, do not install the rubber feet.

Mount the switcher to a rack shelf as follows:
1

.

If rubber feet are installed on the bottom of the unit,

remove them.

2

.

Mount the switcher on the rack shelf, using two 4-40 x

3/16" screws in opposite (diagonal) corners to secure the

switcher to the shelf.

3

.

Install blank panel(s) or other unit(s) to the rack shelf.

6" Deep Rack Shelf

Front false
faceplate
uses 2
screws.

HalfRack6inchRackShelf

1/2 Rack Width Front False
Faceplate

Use 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

Mounting the switcher on a 6-inch deep rack shelf