Filling the reservoir while ironing

• When the water in the reservoir is below the minimum level, the no water LED (7) lights

up and the iron stops producing steam.

• Lift the reservoir water fill cover (1) and fill the water reservoir (2) without overflowing.

Once finished, lower the water fill cover (1) completely.

• The appliance is ready to continue ironing.

MAINTENANCE

Cleaning the boiler

The boiler must be cleaned after 20 hours of operation, in order to prevent limescale from

forming.

The boiler cleaning LED (6) starts blinking when the boiler must be cleaned.

However, you can start ironing. Follow the “Sequence of operations” below to clean the

boiler.

ATTENTION!
The boiler must only be cleaned when cold.

NOTE:

Failure to carry out this operation will make the warranty null and void.

Sequence of operations:

• Press the ON/OFF button (12).

• Disconnect the plug (13) from the socket.

• Let the boiler cool down for at least 4 hours.

• Place the boiler on a wash basin.

• Shake the base to help the limescale chips detach (Fig. B).

• Loosen the cleaning cap (11) by turning it anti-clockwise (Fig. C).

• Let the water and limescale drain from the hole.

• Shake the boiler once again for the remaining water and limescale chips to come out.

• Tighten the cleaning cap (11) by turning it clockwise.

• Refill the water reservoir (2) before using the boiler again.

• Insert the plug (13) in the socket.

• The boiler cleaning LED (6) continues blinking: press the ECO button (3) until the LED

goes off.

Make sure the cleaning cap (11) is tightened well.

Do not clean the boiler with detergents, anti limescale products, vinegar

or any other substance.