OM-01228

UNIT SERIES

PAGE B - 2

INSTALLATION

Gorman‐Rupp distributor or the factory to deter­

mine the repair or updating policy. Do not put the

pump into service until appropriate action has

been taken.

UNIT INSTALLATION

Lifting

Pump unit weights will vary depending on the

mounting and drive provided. Check the shipping

tag on the unit packaging for the actual weight, and

use lifting equipment with appropriate capacity.

Drain the pump and remove all customer‐installed

equipment such as suction and discharge hoses

or piping before attempting to lift existing, installed

units.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam­
age to equipment.

Mounting

Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount­
ing is essential for proper operation.

The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra­
tion.

Specifications

See Table 1 for typical pump specifications.

Table 1. Pump Specifications

Pump
Model

Voltage

Phase

Horse­

power

Motor

RPM

Cycle

Suction

Coupler

Discharge

Coupler

02D3

115/230

1

1

3450

60 Hz

1-1/2”

1-1/2”

See Table 1 for typical pump specifications.

Table 2. Unit Specifications

Power
Cable

Reel

Assembly

Suction

Hose

Ground

Wire

Standpipe Length

(Min) - (Max)

50 Ft.

(15,2 M.)

1-1/2” x 15 Ft.

38,1 MM x 4,6 M

10 Ft.

(3,1 M.)

42 Ft.

(12,8 M.)

Discharge

Hose

1-1/2” x 15 Ft.

38,1 MM x 4,6 M

7.25 Ft. - 12 Ft.

2,2 M - 3,7 M

Product Compatibility

The cleanout hose in the hose and reel assembly is
“Ambassador Hardwall 559N” hose manufactured
by Goodyear Tire and Rubber Company. It is com­
patible with most hydrocarbon products. Consult
the Goodyear Tire and Rubber Company or

www.goodyear.com for specific product compati­
bility.

Positioning Unit and Setup

Figure 2 shows a typical installation of the Tank­
leenor

R

system.