Gorman-Rupp Pumps T8A60S-4045H 1514489 and up User Manual

Page 49

Advertising
background image

OM-06522

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E - 22

fill cover and tighten it. Refer to OPERATION, Sec­
tion C, before putting the pump back into service.

LUBRICATION

Seal Assembly

(Figure 4)

Before starting the pump, remove the vented plug
(9) and fill the seal cavity with approximately 86
ounces (2,5 liter) of SAE No. 30 non‐detergent oil to
the middle of the sight gauge (25)

and maintain it at

the middle of the gauge. Clean and reinstall the
vented plug. Maintain the oil at this level.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Bearings

(Figure 4)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu­
larly through the sight gauge (26)

and maintain it at

the middle of the gauge. When lubrication is re­
quired, add SAE No. 30 non‐detergent

oil through

the hole for the air vent (10). Do not over‐lubricate.

Over‐lubrication can cause the bearings to over‐
heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with approximately 20
ounces (0,6 liter) clean oil. Change the oil more fre­
quently if the pump is operated continuously or in­
stalled in an environment with rapid temperature
change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local engine representative.