Operation - section c – Gorman-Rupp Pumps 112D60-B-TCD914L6 1520501 and up User Manual

Page 15

Advertising
background image

OM-06592

10 SERIES

OPERATION

PAGE C - 1

OPERATION - SECTION C

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and
decals attached to the pump.

This pump is designed to handle most
non‐volatile, non‐flammable liquids
containing specified entrained solids.
Do not attempt to pump volatile, corro­
sive or flammable liquids which may
damage the pump or endanger person­
nel as a result of pump failure.

The pump end is designed to operate at
???? RPM through a gearbox with a 1.6:1
ratio at a maximum input speed of ????
RPM. Make certain that input speed does
not exceed this RPM. Operation at higher
RPM can cause pump components to be
damaged or destroyed.

PRIMING

Install the pump and piping as described in IN­
STALLATION
. Make sure that the piping connec­
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri­
cated (see LUBRICATION in MAINTENANCE
AND REPAIR
).

This pump is self‐priming, but the pump should
never be operated unless there is liquid in the
pump casing.

Never operate this pump unless there is
liquid in the pump casing. The pump will

not prime when dry. Extended operation of
a dry pump will destroy the seal assembly.

Add liquid to the pump casing when:

1. The pump is being put into service for the

first time.

2. The pump has not been used for a consider­

able length of time.

3. The liquid in the pump casing has evapo­

rated.

Once the pump casing has been filled, the pump
will prime and reprime as necessary.

After filling the pump casing, reinstall
and tighten the fill plug. Do not attempt
to operate the pump unless all connect­
ing piping is securely installed. Other­
wise, liquid in the pump forced out un­
der pressure could cause injury to per­
sonnel.

To fill the pump, remove the pump casing fill cover
or fill plug in the top of the casing, and add clean
liquid until the casing is filled. Replace the fill cover
or fill plug before operating the pump.

STARTING

Consult the operations manual furnished with the
engine.

OPERATION

Gearbox Check

Check the gearbox lubrication before operation,
and periodically thereafter. See the gearbox man­
ufacturer's literature for recommendations.

Lines With a Bypass

If a Gorman‐Rupp Automatic Air Release Valve has
been installed, the valve will automatically open to

Advertising