Gorman-Rupp Pumps 16C20-F5L 1338868 and up User Manual

Page 37

Advertising
background image

10 SERIES

OM−02616

MAINTENANCE & REPAIR

PAGE E − 16

larly through the sight gauge (39)

and maintain it at

the middle of the gauge. When lubrication is re-
quired, add SAE No. 30 non-detergent oil through
the hole for the oil hole cover (20). Do not over-lu-
bricate. Over-lubrication can cause the bearings to
over-heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.

Under normal conditions, drain the intermediate
once each year and refill with approximately 7.5
ounces (22 mL) of clean oil. Change the oil more
frequently if the pump is operated continuously or
installed in an environment with rapid temperature
change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local Deutz engine representative.

Advertising