Troubleshooting - section d – Gorman-Rupp Pumps 14C20-F3L 1319349 and up User Manual

Page 19

Advertising
background image

OM−03413

10 SERIES

TROUBLESHOOTING

PAGE D − 1

TROUBLESHOOTING − SECTION D

Review all SAFETY information in Section A.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man-

ual.

2. Switch off engine ignition and dis-

connect the positive battery cable

to ensure that the pump will remain
inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO PRIME

Not enough liquid in casing.

Suction check valve contaminated or
damaged.

Air leak in suction line.

Lining of suction hose collapsed.

Leaking or worn seal or pump gas-
ket.

Suction lift or discharge head too
high.

Strainer clogged.

Add liquid to casing. See PRIMING.

Clean or replace check valve.

Correct leak.

Replace suction hose.

Check pump vacuum. Replace leak-
ing or worn seal or gasket.

Check piping installation and install
bypass line if needed. See INSTAL-
LATION.

Check strainer and clean if neces-
sary.

PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE

Air leak in suction line.

Lining of suction hose collapsed.

Leaking or worn seal or pump gas-
ket.

Strainer clogged.

Suction intake not submerged at
proper level or sump too small.

Correct leak.

Replace suction hose.

Check pump vacuum. Replace
leaking or worn seal or gasket.

Check strainer and clean if neces-
sary.

Check installation and correct sub-
mergence as needed.

Advertising