Safety - section a – Gorman-Rupp Pumps 14C20-F3L 1319349 and up User Manual

Page 6

Advertising
background image

10 SERIES

OM−03413

PAGE A − 1

SAFETY

SAFETY − SECTION A

This information applies to 10 Series en-
gine driven pumps. Refer to the manual
accompanying the engine before at-
tempting to begin operation.

Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre-
cautions for each specific application.
Therefore, it is the owner/installer’s re-
sponsibility to ensure that applications
not addressed in this manual are per-
formed only after establishing that nei-
ther operator safety nor pump integrity
are compromised by the installation.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man-

ual.

2. Switch off the engine ignition and

disconnect the positive battery
cable to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

This pump is designed to handle dirty
water containing specified entrained
solids. Do not attempt to pump volatile,
corrosive, or flammable

materials, or

any liquids which may damage the

pump or endanger personnel as a result
of pump failure.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. Suction and dis-
charge hoses and piping must be re-
moved from the pump before lifting.

After the pump has been positioned,
make certain that the pump and all pip-
ing or hose connections are tight, prop-
erly supported and secure before oper-
ation.

Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis-
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.

Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over-
heated pump. Vapor pressure within the
pump can cause parts being disen-
gaged to be ejected with great force. Al-
low the pump to cool before servicing.

Do not operate an internal combustion

Advertising