Gorman-Rupp Pumps 02K3-B 283128 and up User Manual

Page 16

Advertising
background image

OM-01162

0 SERIES

OPERATION

PAGE C - 3

Before checking for the source of the leak, check
the point of installation of the vacuum gauge.

STOPPING

Never halt the flow of liquid suddenly. If the liquid
being pumped is stopped abruptly, damaging
shock waves can be transmitted to the pump and
piping system. Close all connecting valves slowly.

After stopping the pump, lock out or disconnect
the power source to ensure that the pump will re­
main inoperative.

Do not operate the pump against a
closed discharge throttling valve for
long periods of time. If operated against
a closed discharge throttling valve,
pump components will deteriorate, and
the liquid could come to a boil, build
pressure, and cause the pump casing to
rupture or explode.

BEARING TEMPERATURE CHECK

Bearings normally run at higher than ambient tem­
peratures because of heat generated by friction.
Temperatures up to 160

_F (71_C) are considered

normal for bearings, and they can operate safely to
at least 180

_F (82_C).

Checking bearing temperatures by hand is inaccu­
rate. Bearing temperatures can be measured ac­
curately by placing a contact‐type thermometer
against the housing. Record this temperature for
future reference.

A sudden increase in bearing temperatures is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing
lubricant is of the proper viscosity and at the cor­
rect level (see LUBRICATION in Section E). Bear­
ing overheating can also be caused by shaft
misalignment and/or excessive vibration.

When pumps are first started, the bearings may
seem to run at temperatures above normal. Con­
tinued operation should bring the temperatures
down to normal levels.

Cold Weather Preservation

In below freezing conditions, drain the pump to
prevent damage from freezing. Also, clean out any
solids by flushing with a hose. Operate the pump
for approximately one minute; this will remove any
remaining liquid that could freeze the pump rotat­
ing parts. If the pump will be idle for more than a
few hours, or if it has been pumping liquids con­
taining a large amount of solids, drain the pump,
and flush it thoroughly with clean water. To prevent
large solids from clogging the drain port and pre­
venting the pump from completely draining, insert
a rod or stiff wire in the drain port, and agitate the
liquid during the draining process. Clean out any
remaining solids by flushing with a hose.

Advertising