Gorman-Rupp Pumps 02K3-B 283128 and up User Manual

Page 27

Advertising
background image

0 SERIES

OM-01162

MAINTENANCE & REPAIR

PAGE E - 8

BEARING
HOUSING

IMPELLER
SHAFT

IMPELLER

SPRING

RETAINER

DRIVE BAND

BELLOWS

STATIONARY
SEAT

ROTATING
ELEMENT

STATIONARY
ELEMENT

SPRING

RETAINER

IMPELLER

SHIMS

Figure 3. Seal Assembly

This seal is not designed for operation at
temperatures above 160

_F (71_C). Do not

use at higher operating temperatures.

Lay the intermediate bracket (20) on a flat surface
with the impeller side facing up. Subassemble the
stationary element into the stationary seat and use
even pressure to press this subassembly into the
intermediate bracket until it seats squarely against
the shoulder bore.

Install the slinger ring (21) on the impeller shaft.

Carefully slide the assembled intermediate and
stationary portion of the seal over the shaft. Secure
the intermediate to the bearing housing with the
hardware (9, 10 and 11).

Subassemble the rotating element into the retainer
and bellows. Lubricate the I.D. of the bellows with
water and slide this subassembly onto the shaft
until the polished faces contact. Install the seal
spring and spring retainer.

Impeller Installation

Inspect the impeller and replace it if cracked or
badly worn.

For maximum pump efficiency, the impeller should
be centered within the vane plate scroll.

To verify the impeller positioning, measure the
vane plate and impeller as shown in Figure 4. Use
these measurements to calculate the required im­
peller location (dimension E). Add or remove im­
peller adjusting shims (15) until dimension E is ob­
tained.

Advertising