Pump and seal disassembly and reassembly – Gorman-Rupp Pumps 03F3-B 463273 and up User Manual

Page 23

Advertising
background image

0 SERIES

OM-01189

MAINTENANCE & REPAIR

PAGE E - 4

PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY

Review all SAFETY information in Section A.

Follow the instructions on all tags, label and de­
cals attached to the pump.

This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be­
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional view (see Figure 1) and the accompa­
nying parts list.

This manual will alert personnel to known proce­
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per­
sonnel to ensure that only safe, established main­
tenance procedures are used, and that any proce­
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac­
tices.

Before attempting to service the pump, switch off
the power source to ensure that the pump will re­
main inoperative. Close all valves in the suction
and discharge lines.

For power source disassembly and repair, consult
the literature supplied with the power source, or
contact your local power source representative.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man­

ual.

2. Lock out or disconnect the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau­

tiously.

7. Drain the pump.

If this pump is used for volatile and/or
flammable liquids, be certain proper
safety practices are followed before op­
erating or servicing the pump. Provide
adequate ventilation, prohibit smoking,
wear static‐resistant clothing and
shoes. Clean up all fuel spills immedi­
ately after occurrence.

Pump Casing and Wear Ring Removal

Before attempting to service the pump, remove the
pipe plug (27) and drain the pump. Clean and rein­
stall the pipe plug.

To service the wear ring (24), impeller (2), seal as­
sembly (3), or seal plate (9), the pump casing (1)
must be separated from the base and pedestal
(20).

Remove the suction and discharge lines. Remove
the nuts (8) and use a suitable hoist and sling to
separate the pump casing and gasket set (23) from
the seal plate and pedestal.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam­
age to equipment. Suction and dis­
charge hoses and piping must be re­
moved from the pump before lifting.

Tie and tag any leveling shims used under the cas­
ing feet to ease reassembly.

Inspect the wear ring (24) for excessive wear or
scoring. The wear ring is secured in the pump cas­

Advertising