PUMP MAINTENANCE AND REPAIR - SECTION E

MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.

IN GALLONS PER MINUTE AT 60 STROKES PER MINUTE

STATIC

LIFT

IN FEET

STATIC DISCHARGE HEAD IN FEET

5

10

15

20

5

27

26

24

22

25

10

24

21

20

19

20

21

22

21

20

15

19

20

18

20

19

18

17

0

IN LITERS PER MINUTE AT 60 STROKES PER MINUTE

STATIC

LIFT

IN METERS

STATIC DISCHARGE HEAD IN METERS

1,5

3,0

4,6

6,1

102,2

98,4

90,8

83,3

1,5

94,6

90,8

79,5

75,7

71,9

3,0

75,7

79,5

83,3

79,5

75,7

71,9

68,1

75,7

71,9

4,6

68,1

6,1

64,3

0

STANDARD PERFORMANCE TEST DATA FOR 2D ELECTRIC MOTOR DRIVEN PUMP

Based on 70_ F (21_ C) clear water at sea level

with minimum suction lift, using 2 inch (50 mm)
suction hose and 2 inch (50 mm) non-collapsible
discharge hose. Since pump installations are sel-
dom identical, your performance may be differ-
ence due to such factors as specific gravity, eleva-

tion and temperature.

If your pump serial number is followed by an N",
your pump is NOT a standard production model.
Contact the Gorman-Rupp Company to verify per-
formance or part numbers.