Gorman-Rupp Pumps 2D-E.50 1P 1485341 and up User Manual

Page 7

Advertising
background image

D SERIES

OM−01476

PAGE A − 2

SAFETY

Do not install and operate a non-explo-
sion proof motor in an explosive atmo-
sphere. Install, connect, and operate
the motor in accordance with The Na-
tional Electric Code and all local codes.
If there is a conflict between the instruc-
tions in the manual accompanying the
unit and The National Electric Code or
the applicable local code, The National
or local code shall take precedence.

Never install a positive shut-off valve in the
discharge line; discharge restrictions will
cause excessive friction loss resulting in
overloading and destruction of pump and
drive components. It is strongly recom-
mended that unless absolutely necessary,
no positive shut-off valve be installed in the
suction line; excessive restriction will
cause incomplete filling of the diaphragm
chamber and result in shortened dia-
phragm life.

Advertising