OM-06260

PA SERIES

OPERATION

PAGE C - 3

shock waves can be transmitted to the pump and
piping system. Close all connecting valves slowly.

Reduce the throttle speed slowly and allow the en­
gine to idle briefly before stopping.

Consult the engine operations manual and the
manual accompanying the original unit before
stopping the unit.

After stopping the pump, switch off the engine igni­
tion and remove the key to ensure that the pump
will remain inoperative.

PERIODIC CHECKS

Seal Cavity And Bearing Lubrication

Both the seal and bearing cavities were fully lubri­
cated at the factory. Check the lubrication levels
before startup, and regularly thereafter as indi­
cated in Section E, Maintenance and Repair.
When lubrication is required, use only SAE No. 30
non‐detergent oil.

Bearing Temperature Check

Bearings normally run at higher than ambient tem­
peratures because of heat generated by friction.
Temperatures up to 160

_

F (71

_

C) are considered

normal for bearings, and they can operate safely to
at least 180

_

F (82

_

C).

Checking bearing temperatures by hand is inaccu­
rate. Bearing temperatures can be measured ac­
curately by placing a contact‐type thermometer
against the housing. Record this temperature for
future reference.

A sudden increase in bearing temperatures is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing
lubricant is of the proper viscosity and at the cor­
rect level (see LUBRICATION in Section E, Main­
tenance and Repair
). Bearing overheating can
also be caused by shaft misalignment and/or ex­
cessive vibration.

When pumps are first started, the bearings may
seem to run at temperatures above normal. Con­
tinued operation should bring the temperatures
down to normal levels.

Air Compressor

Consult the manual accompanying the air com­
pressor and preform all duties and checks as indi­
cated.

COLD WEATHER PRESERVATION

In below freezing conditions, drain the pump to
prevent damage from freezing. Also, clean out any
solids by flushing with a hose. Operate the pump
for approximately one minute; this will remove any
remaining liquid that could freeze the pump rotat­
ing parts. If the pump will be idle for more than a
few hours, or if it has been pumping liquids con­
taining a large amount of solids, drain the pump,
and flush it thoroughly with clean water. To prevent
large solids from clogging the drain port and pre­
venting the pump from completely draining, insert
a rod or stiff wire in the drain port, and agitate the
liquid during the draining process. Clean out any
remaining solids by flushing with a hose.