Gorman-Rupp Pumps SE2C3A 115V 1P 1483930 and up User Manual

Page 10

Advertising
background image

OM−06493

SE SERIES

PAGE B − 3

INSTALLATION

torque could cause the pump to roll during opera-
tion.

The pump should be independently secured and
supported by the lifting device fitted on the pump.
If the application involves a lot of debris, protect the
pump from excessive wear and clogging by sus-
pending it in a perforated barrel or culvert pipe. If

the bottom is heavily sludge-covered, rest the
pump on support blocks or suspend it from a raft
or similar device near the surface of the liquid. See
Figure B-1 for typical pump installations.

All liquid entering the pump must pass through a
strainer screen. Any spherical solids which pass
through the screen will pass through the pump.

BY BAIL

IN PERFORATED CULVERT PIPE

ON SUPPORTS

Figure B-1. Typical Pump Installations

Piping

No suction piping is required in a standard installa-
tion. This pump is provided with a suction strainer
to prevent large solids from clogging the impeller.

To determine the size of the discharge connection,
see Table B-1. Either hose or rigid pipe may be
used. To facilitate mobility and maintenance, it is
recommended that the discharge line be fitted with
a quick disconnect fitting near the pump. The dis-
charge line must be independently supported to
avoid strain and vibration on the pump.

Either hose or rigid pipe may be used to make dis-
charge connections. For maximum pumping ca-
pacity, keep the line as short and straight as pos-
sible. Elbows and fittings used in discharge lines
increase friction loss, minimize their use.

It is recommended that a check valve or throttling
valve be installed in the discharge line to control si-
phoning or back flow when the pump is shut off.

ELECTRICAL CONNECTIONS

Install and operate this pump in accor-
dance with the National Electrical Code
and all local codes. Have a qualified
electrician perform all checks and con-
nections in this section.
Never attempt to alter the length of the
pump motor cable or to repair it with a
splice. The power cable and pump mo-
tor must be kept completely waterproof.

Advertising