Troubleshooting - section d – Gorman-Rupp Pumps SE2C3A 115V 1P 1483930 and up User Manual

Page 18

Advertising
background image

OM−06493

SE SERIES

TROUBLESHOOTING

PAGE D − 1

TROUBLESHOOTING − SECTION D

Review all SAFETY information in Section A.

The following precautions should be
taken before attempting to service the
pump; otherwise, injury or death could
result.

1. Familiarize yourself with this man-

ual.

2. Unplug the power cable from its re-

ceptacle to ensure that the pump
will remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates or
plugs.

5. Close the discharge valve (if

used).

The electrical power used to operate
this pump is high enough to cause inju-
ry or death. Obtain the services of a qu-
alified electrician to troubleshoot, test
and/or service the electrical compo-
nents of this pump.

NOTE

Many of the probable remedies listed below re-
quire use of electrical test instruments; for specific
procedures, see ELECTRICAL TESTING following
the chart.

Table 1. Trouble Shooting Chart

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO START,
OVERLOAD UNIT NOT
TRIPPED
(MANUAL MODE)

(AUTOMATIC MODE)

Power source incompatible with
pump motor.

No voltage at line side of power cable
connection.

Open circuit in motor windings or
power cable.

Defective motor.

Liquid level device or control circuits
improperly connected to main con-
trol box.

Level sensing device(s) improperly
positioned.

Level sensing device(s) fouled with
mud or foreign material.

Float type sensing device(s) tangled
or obstructed.

Correct power source.

Check power source for blown fuse,
open breaker, broken lead, or loose
connection.

Check continuity.

Check for and replace defective unit.

Check wiring diagrams; correct or
tighten connections.

Position device(s) at proper level.

Clean sensing device(s).

Check installation for free movement
of float.

Advertising