OM-06258

S SERIES PUMPS

PAGE B - 4

INSTALLATION

ting near the pump. The discharge line must be in­
dependently supported to avoid strain and vibra­
tion on the pump.

Either hose or rigid pipe may be used to make dis­
charge connections. For maximum pumping ca­
pacity, keep the line as short and straight as pos­
sible. Elbows and fittings used in discharge lines
increase friction loss, minimize their use.

It is recommended that a check valve or throttling
valve be installed in the discharge line to control si­
phoning or back flow when the pump is shut off.

ELECTRICAL CONNECTIONS

Install and operate this pump in accor­
dance with the National Electrical Code
and all local codes. Have a qualified
electrician perform all checks and con­
nections in this section.
Never attempt to alter the length of the
pump motor cable or to repair it with a
splice. The power cable and pump mo­
tor must be kept completely waterproof.
Serious damage to the pump and injury
or death to personnel can result from
any alteration to the cable.

Control Box Installation

The pump is designed to be operated
through the control box furnished with
the pump. The control box provides
overload protection and power control.
Do not connect the pump motor directly
to the incoming power lines.

The control box is a rainproof enclosure with a pad­
lockable front cover. The enclosure is not de­
signed to be watertight, and should not be sub­
merged.
Refer to the control box manual for enclo­
sure dimensions and parts.

Secure the control vertically on a level surface,
above flood level. The box should be easily acces­

sible to the operator, and located close enough to
the pump to avoid excessive voltage drop due to
cable length (see Pump Power Cable Connec­
tion
). After the box is installed, make certain the
front cover latches properly.

Failure to mount the control box vertically
on a level surface may affect operation of
the pump controls.

Field Wiring Connections (Incoming Power)

The electrical power used to operate
this pump is high enough to cause inju­
ry or death. Obtain the services of a
qualified electrician to make all electri­
cal connections. Make certain that the
pump and enclosure are properly
grounded; never use gas pipe as an
electrical ground. Be sure that the in­
coming power matches the voltage and
phase of the pump and control before
connecting the power source. Do not
run the pump if the voltage is not within
the limits.

Do not connect the pump motor directly
to the incoming power lines. The pump
motor is designed to operate through a
Gorman‐Rupp approved control box
which provides overload protection and
power control; otherwise, the pump
warranty will be voided. Make certain
that the pump and control box are prop­
erly grounded. Install and operate the
control box in accordance with the Na­
tional Electric Code and all local codes.
Failure to follow these could result in in­
jury or death to personnel.