Gorman-Rupp Pumps S8A1-E95 575/3 1429751 and up User Manual

Page 50

Advertising
background image

S SERIES PUMPS

OM-06258

MAINTENANCE AND REPAIR

PAGE E - 24

Table E-2. Oil Quantity

Pump Model

Seal Cavity

Motor Cavity

S8A

576 ounces (17 liters)

176 ounces (5,2 liters)

Table E-3. Pump Oil Specifications

Specifications:

Type

Premium high viscosity index, anti‐wear hydraulic oil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity (SSU @ 104

_F [40_C])

110 to 155

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dielectric

26,000 (volts‐min)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Acceptable alternate suppliers:

Gulf Oil Company

Gulf Harmony AW Hydraulic Fluid MG 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Texas Oil Company

Rando HD 32 or HD AZ 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sun Oil Company

Sunvis 816 or 916

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BP (Also Boron)

Energol‐HLP 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shell Oil Company

Tellus 32, Tellus T‐23 or T32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity (SSU @ 210

_F [100_C])

40 to 50

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Recommended supplier:

Gulf Oil Company

Gulf Harmony 32 AW

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ARCO

Duro 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Exxon (Also Esso)

Nuto H 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Petro‐Canada

Harmony HVI 22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Motor Housing Cavity

With the pump in an upright position, remove the
pipe cap (27) on the top of the pump and the oil lev­
el plug (21) in the side of the pump. See Table E-2
and add the recommended grade of lubricant
(Table E-3) to the motor cavity until the oil begins
to drain from the oil level plug opening. Apply `Loc­
tite Pipe Sealant With Teflon No. 592' or equivalent
sealant to the threads of the oil level plug and pipe

cap and reinstall the plug and pipe cap. Maintain
the oil at this level
.

Never attempt to fill the motor cavity
through the drain plug (16) opening or the
oil level plug (21). A volume of air must be
trapped above the motor to permit thermal
expansion of the motor oil.

Advertising