Problem cause correction – Liberty Pumps 405HV User Manual
Page 4

©Copyright 2014 Liberty Pumps Inc. All rights reserved
4
NOTE: Liberty Pumps, Inc. assumes no responsibility for damage or injury due to disassembly beyond float removal in the field.
Disassembly, other than at Liberty Pumps or its authorized service centers, automatically voids warranty.
Problem
Cause
Correction
Pump will not turn
on or shut off.
Blown fuse or other interruption of
power; improper voltage.
Check that the unit is securely plugged in.
Have an electrician check all wiring for proper
connections and adequate capacity.
Plugged vent, or quick-vent in use.
Be sure that an unrestricted vent at least 1-¼”
in diameter is in use. Quick-vents shall not be
used.
Defective switch or build-up on tank
wall restricting free movement of
float switch.
*Remove access cover and check that float is
free to move. If build-up restricts float, clean
and reinstall. If defective, replace switch.
Pump runs or hums
but does not pump.
Discharge is blocked or restricted.
Check the discharge line for blockage,
including ice if the line passes through or into
cold areas.
Check valve is stuck closed or
installed wrong.
Remove and examine for freedom of
operation and proper installation.
Total lift height has been reached
(see Fig. 2)
Try routing pipe to a lower level. If not
possible, another pumping station may be
required at a level of roughly half the total lift.
Pump impeller is jammed.
*Disassemble the receiver and bottom base
of pump. Remove foreign material.
Reassemble.
Trap or inlet piping is clogged.
Check the trap and inlet piping for restrictions.
Pump short-cycles.
Plugged vent, or quick-vent in use.
Be sure that an unrestricted vent at least 1-¼”
in diameter is in use. Quick-vents shall not be
used.
Defective switch.
*Remove access cover and check that float is
free to move. If build-up restricts float, clean
and reinstall. If defective, replace switch.
Check valve was not installed, is
stuck open, or is leaking.
Remove and examine for freedom of
operation and proper installation.