Elmo Rietschle C-VLR 301 User Manual

Page 22

Advertising
background image

22

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Maintenance and repair

1

2

D

s

1

f

1

Fig. 5 Air fi ltering

D

Suction fl ange

f

1

Mesh

fi lter

s

1

Screws

7.2.2 Air fi ltering

NOTICE

Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine.

Intake air fi lter:
The mesh fi lter (Fig. 5/f

1

) must be cleaned by rinsing

out or purging or replaced more or less often de-
pending on how dirty the discharged medium is.
Remove the suction fl ange (Fig. 5/D) after undoing
the screws (Fig. 5/s

1

).

Also check the valve seating for contamination.
Assemble in reverse order.

WARNING

Risk of injury when handling compressed air
When blowing through with compressed air, solid
particles may be carried along or powder dust swir-
ling around may cause injury to the eyes.
Therefore, when cleaning with compressed air always
wear goggles and a dust mask.

Fig. 6 Blowing out the mesh fi lter

1 Mesh

fi lter

2 Compressed

air