Maintenance and repair

n

2

m

s

5

q

v

k

7.2.3 Coupling

The coupling sprocket (Fig. 7/k)) is subject to wear
and must be checked regularly (at least once a year).

CAUTION

Defective coupling sprocket
Defective sprockets may lead to the rotor shaft
breaking.

To check the coupling switch the motor (Fig. 7/m)
off and ensure that it cannot be switched on again.
Undo the screws (Fig. 7/s

5

) on the motor fl ange. Re-

move the motor with the coupling half on the motor
side (Fig. 7/q) from the fanhousing (Fig. 7/n

2

) axi-

ally and suspend using a lifting tool. If the sprocket
(Fig. 7/k) is damaged or worn, then replace it. The
fan (Fig. 7/v) should also be checked for damage
from time to time and replaced if necessary.

NOTICE

Frequent starting up and high ambient tem-
perature
The service life of the sprocket (Fig. 7/k) is re-
duced.

Re-assemble in reverse order.

Fig. 7 Coupling

k

Coupling sprocket

m

Motor

n

2

Fan housing

q

Coupling half on the motor side

s

5

Screws

v Fan