5.5

Filling with lubricating oil

a) Fill the lubricating oil (for suitable types see

„Maintenance“) for the gear wheels and bearings
at the oil fi lling point (Fig. 2/H) up to the middle
of the sight glass (Fig. 2/I).

b) Close the oil fi lling point.

5.6 Connecting

the

motor

DANGER

Danger of death if the electrical installation has
not been done professionally.
The electrical installation must only be done by a
qualifi ed electrician observing EN 60204. The ope-
rating company has to provide the main switch.

a) The motor‘s electrical data is given on the data

plate (Fig. 2/N) or on the motor data plate (Fig. 2/
P

1

). The motors comply with DIN EN 60034

and are in protection class IP 55 and insulation
class F. The appropriate connection diagram is
located in the motor‘s terminal box (not for the
plug connection version). The motor data must
be compared with the data of the existing mains
network (current type, voltage, network frequen-
cy, permitted current value).

b) Connect the motor via the plug connection

(Fig. 2/J) or a motor protection switch (for safety
reasons a motor protection switch is required
and cable fi tting must be provided to provide
strain relief for the connection cable). We recom-
mend using motor protection switches with de-
layed switch off, depending on possible excess
current. Temporary excess current may occur
when the machine is started cold.

NOTICE

Power supply

The conditions at the installation location must
match the information on the motor data plate.
Without derating the following is permissible:
• ± 5% Voltage deviation
• ± 2% Frequency deviation

Advertising