Elmo Rietschle V-KTR 100/140 User Manual

Page 13

Advertising
background image

13

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Bauj./Nr. 09

S1 5,50 / 6,50

kW

Typ KTR 100 (01)

+ 0,60 / - 0,60 bar

2843970

100 / 120 m³/h

EN 60034

1460 / 1745 min

-1

1027630137

3~

Mot.

Set up and operation

6

1

7

8

9

10

3

4

5

2

4.2 Description

The V-KTR range has a connecting thread on the pressure side and on the suction side.. The aspirated air
is cleaned by an inbuilt fi ne micro fi lter. The carbon dust caused by the scoring of the discs can also be
separated by an integral fi lter if necessary. A fan between the compressor housing and the motor provides
intensive air cooling. The compressor housing is located in a sound cover. The compressed air is cooled by
a cooling segment.
The machines are driven by standard fl anged three-phase motors using a coupling.
Pressure and vacuum can be adjusted to the required levels, however, they are limited to a maximum point.

4.3

Areas of application

These dry running rotary vane pressure vacuum pumps models V-KTR 100 and V-KTR 140 are suitable for
creating pressure and vacuum at the same time. Constant operation is permissible.

All models have nominal capacities of 100 and 140 m

3

/hr operating at 50 cycles. The pressure and vacuum

limits (bar) are indicated on the data plate (Fig. 2/N). The tables showing capacity against pressure and vac-
uum can be seen in data sheet D 461.

These dry running machines are suitable for conveying air with a relative humidity of 30 - 90%.

If the unit is switched on more frequently (at regular intervals of about 10 times an hour) or at
higher ambient temperatures and intake temperatures, the excess temperature limit of the motor
winding and the bearings may be exceeded.
Please contact the manufacturer should the unit be used under such conditions

If it is installed in the open air the unit must be protected from environmental infl uences, (e.g. by a
protective roof).

Fig. 3 Data plate

1

Type/ Size (mechanical version)

2

Year of construction

3 Motor

design

4 Serial

number

5 Item

no

6

Overpressure / Vacuum

7

Pumping capacity 50 Hz / 60 Hz

8 Speed

50

Hz / 60

Hz

9

Motor output 50 Hz / 60 Hz

10 Operating

mode

4.1.1 Data plate

Advertising