Elmo Rietschle V-KTR 100/140 User Manual

Page 27

Advertising
background image

27

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Overpressure or vac-
uum not achieved

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Discs are worn or damaged

Replace discs

Section 7.2.2
Section 7.4

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

The blow out fi lter cartridge is
dirty.

Clean or replace the fi lter
cartridges

Section 7.2.3
Section 7.4

The regulating valves are dirty
so that the permissible pres-
sure and/or vacuum values
have been exceeded.

Clean or replace the regulat-
ing valve

Section 7.2
Section 7.4

The machine makes
a abnormal noise

The compressor housing is
worn (chatter marks)

Repair by manufacturer or
authorised workshop

Elmo Rietschle
Service

A regulating valve is vibrating

Replace the valve

Section 7.4

Discs are damaged

Replace discs

Section 7.2.2
Section 7.4

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.

Advertising