Elmo Rietschle V-VCE 25/40 User Manual

Page 18

Advertising
background image

18

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Commissioning and decommissioning

X

X

6.1.1 Checking the rotation direction

The drive shaft direction of rotation is shown by

the rotation direction arrow (Fig. 2/O) on the mo-
tor fl ange.

a) Start the motor briefl y (max. two seconds) to

check the direction of rotation. When looking at
the motor fan, it must rotate clockwise.

NOTICE

Incorrect direction of rotation
Operating in the wrong direction of rotation leads
to damage to the machine.
Use a phase sequence indicator to check the direc-
tion of rotation (anti-clockwise rotating fi eld).

b) After correcting the direction of rotation if nec-

essary, start the motor again and stop it again
after 2 minutes in order to top missing oil up to
the upper edge of the sight glass (Fig. 2/I). This
topping up at the fi lling point (Fig. 2/H) must be
repeated until all the oil pipes have been fi lled
completely. The fi lling point must not be open
when the pump is running.

6.1.2 Setting the operating range

Version

(09):

The operating range can be set by turning the
adjusting bolt (Fig. 2/X, 4/X).

Fig. 4 Version (09): Setting the operating range

X Adjusting

bolt

Fine vacuum::
50 Hz: 0,5 to 130 mbar (abs.)
60 Hz: 0,5 to 100 mbar (abs.)

Rough vacuum:
50 Hz: 10 to 500 mbar (abs.)
60 Hz: 10 to 400 mbar (abs.)

Advertising
This manual is related to the following products: