Maintenance and repair

f

4

f

4

h

1

f

3

g

1

f

1

s

1

D

U

7.2.1 Air fi ltering

NOTICE

Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine..

Intake air fi lter:
The micro fi lter (Fig. 5/f

1

) must be cleaned by rinsing out

or purging or replaced more or less often depending
on how dirty the discharged medium is.
Remove the fi lter housing (Fig. 5/D) after undoing
the screws (Fig. 5/s

1

). Remove and clean the micro

fi lter.

Gas ballast valve fi lter:
The pumps work with a gas ballast valve (Fig. 4/U).
The inbuilt fi lter disc (Fig. 6/f

3

) and micro fi lter discs

(Fig. 6/f

4

) must be cleaned more or less often by

purging depending on how dirty the medium fl ow-
ing through is. By undoing the countersunk screw
(Fig. 6/g

1

) and removing the plastic cover (Fig. 6/h

1

)

the fi lter parts can be removed for cleaning.
Re-assemble in reverse order.