Malfunctions: Causes and elimination

8

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Machine is
switched off
by the motor
protection
switch

Mains voltage/ Frequency
does not correspond with the
motor data

Check by qualifi ed electrician

Section 5.5

Check all electrical connec-
tions

Motor protection switch is not
set correctly

Motor protection switch is
triggered too quickly

Use a motor protection switch with an
overload-dependent delayed switch
off that takes into consideration the
short term excess current at start up
(version with short circuit and over-
load trigger as per VDE 0660 Part 2
orIEC 947-4)

Blower operates without con-
nection to a system

Connect system

Section 5.3

Insuffi cient
suction ca-
pacity

Filter insert is full

Empty fi lter insert

Section 7.2.1

Suction pipe is too long or too
narrow

Check the the suction pipe

Section 5.3

Machine or system leaking

Check the pipework and screw con-
nections for leaks and to ensure that
they are fi rmly seated

Section 7.2

Machine gets
too hot

Ambient or intake temperature
is too high

Ensure it is being used properly

Section 2.3

Blower sucks too little air

Check the rotation direction resp. cross
sections of the pipes

Section 6.1.1
Section 5.3

Filter insert is full

Empty fi lter insert

Section 7.2.1

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.