Safety instructions


1.4

Application as directed

Validity of the Operating Instructions

These Operating Instructions are valid for G-BH1e series side channel blowers in conjunction with
frequency inverters equipped with the following frequency inverters:



 

2FC

4

xxx

-

1NE00 1x

35

Type

Supply voltage
4 = 400 V/500 V

Power
(e.g.152 = 15 ´ 10

2

W = 1,5 kW)

(e.g.. 752 = 75 ´ 10

2

W = 7,5 kW)

1NE00 = integrated inverter

Hardware version

Software version

nash_elmo Industries GmbH
Industriestrasse 26
D-97616 Bad Neustadt

Type

Input

Output

Prod.-ID

Version

Prod.-No.

Ser.-No.

1

3

2

ne2bhxn014

Fig. 2: Typschild

These Operating Instructions

 contain instructions bearing on transport and

handling, installation, commissioning,
operation, shut−down, storage, servicing and
disposal,

 must be completely read and understood by

all operating and servicing personnel before
beginning to work,

 must be strictly observed,

 must be available at the site of operation in a

complete and perfectly legible condition.

Operating and servicing personnel

 These persons must be trained and

authorized for the work to be carried out.

 Work on electrical installations may be carried

out by trained and authorized electricians
only.

G-BH1e series side channel blowers in
conjunction with frequency inverters

 are

pump−motor units for generating vacuum

or gauge pressure.

 are used to extract, pump and compress the

following gases:

–

Air,

–

Non−flammable, non−aggressive,
non−toxic and non−explosive gases or
gas−air mixtures.

–

With differing gases/gas−air mixtures,
inquire with the manufacturer.

 are intended for industrial applications.

 are designed for continuous operation:

–

With increased switch−on frequency (at
equal intervals of approx. 5 times per hour)
or increased gas entry temperature and
ambient temperature, the limit
overtemperature of the winding and the
bearings can be exceeded.

–

Consultation with the manufacturer is
required for operating conditions of this
kind.

 are equipped with a three−phase drive motor

with mounted frequency inverter.

 are available in the following models:

–

single−impeller (single−stage)

–

two−impeller (two−stage) for increased
pressure difference

–

two−impeller (double−flow) for increased
delivery volume

During operation the limit values listed under
"Technical data" must always be complied with.