GB

-21-

To achieve pump IP protection, network cable should be lead over the inlet and then

crimped to a connector. Ethernet plug is galvanicaly insulated, but the rest of the

cabling could still present shock hazard. All connections should be made with the

power turned off.

If more than one pump will be connected into network, each individual pump should

have its IP address and NetBIOS name changed and noted. That will prevent

network collisions and provide naming service in relation to pump function.

5. c

OmmunicatiOn

and

cOntrOl

5.1

c

onTrol

lighT

Control light on the front panel provides fast overview over pump operation. Blue color signalizes

correct operation while red indicates an error.

blue light

Blinking

Pump is in standby and not pumping water.

On

Pump is operating as set.

Red light indicates error by blinking error codes. Sequence of blinks is interrupted by a pause.

The number of blinks between two pauses is the error code.

red light

Error code

Description

1

Motor is lightly loaded. This indicates that the pump is probably running dry –

fill the system (might need unairing)

2

Pump can not start. Rotor might be blocked – remove head of pump and

check if the rotor turns freely between hydraulic ceiling and stator

3

Motor has overheated – too hot medium, over isolated head of pump or non-

functioning motor

4

Frequency converter error – pump has or will have error – call professional

5

Stator or rotor faulty – call professional

If the pump is unresponsive, disconnect and connect it back to the electrical grid.

5.2

d

igiTal

inpuTs

Electrical properties

Maximum input voltage

32V DC

Input impedance

~5kΩ

Logical »1« voltage

>8V

Logical »0« voltage

<2V

Insulation

To supply voltage: 4kV@1s, 275V permanent.