ABUS FU8006 Secvest 2WAY Wireless Alarm Control Panel (UK, DK, IT) Operating instructions User Manual
Page 31

31
with the smallest number.
For example: An alarm is
triggered in the following
zones in the sequence
described below:
Zone 26
Partition 3
Zone 25
Partition 1
Zone 3
Partition 1
The following can be heard
on the system:
“The partition is unset!
Attention! There has been
an alarm!
<announcement zone 25>,
<announcement zone 26>.
A reset is required.”
Mains Fail Rep.
Menu
Æ Facilities on/off Æ Mains Fail Rep. Yes*
Mains Fail Rep. No
x If you select “Mains Fail Rep. No”, then a
fault in the mains supply voltage will not
be displayed and not be communicated.
x Display – 0 no display of the
warning triangle on the right
x Event log – no entry
x Communication:
ALARMS – no transmission
Speech dialler – no
notification
SMS – no transmission
Display-Contrast
Contrast settings
18.8. Test
This menu is used to test the different alarm centre functions.
Select the “Test” menu item.
Select the function you wish to test.
To end the test, select Back.