Setting the camera output, Live view, Settings – ABUS TVVR30004 Operating instructions User Manual

Page 77

Advertising
background image

Live view

77

Settings

Note

The live view can be set as follows.

Open the main menu, then click on “Configuration”. Then
click on “Liveview”:

The following settings are available in the TAB “General”:

Video Output In-
terface

VGA/HDMI, Main CVBS

Select the connection where the set-
tings are changed

Live View Mode

Different camera layouts

Dwell Time

Switching time between the individu-
al cameras and the sequence dis-
play

Display the status
bar

Activate/deactivate the status bar

Event Output

Allocate monitor for the output of
events

Full Screen Moni-
toring Duration

in seconds, where the event on the
allocated monitor will be displayed.

Post Event Dis-
play Time

in seconds, the duration of the Pop-
up window when an event occurs.

Note

The BNC output can be used either for a spot
monitor or a separate monitor.

NoteVGA monitor connected:

A connected VGA monitor automatically becomes
the main monitor where the audio output is also
assigned. The BNC output Video Spot Out output
displays the cameras in sequence and in full
screen.

No VGA monitor connected

If during the boot process of the DVR the VGA cable is not
connected, the main video signal is displayed at BNC output .
Connect the VGA cable and reboot the DVR in order to display
the main video signal at the VGA output.

Setting the camera output

You can display a maximum of 4 cameras simultaneously
in the live view.

1.

Click on the TAB “View”.

2. Select the display mode.

1 x 1

2 x 2

3. The camera signal is assigned to the corresponding

image section using the navigation keys.

“X” means that this camera is not displayed.

4. Click on Apply to accept the settings.

























Advertising