4 rf connection, 5 verifying transponder operation – Alpha Technologies IDH3 User Manual

Page 15

Advertising
background image

15

745-420-B0-001 Rev. A

2.0

Transponder Installation, continued

2.4 RF

Connection

Connect the RF drop to the RF connector on the transponder. The drop must have a properly
installed ground block in or on the power supply enclosure. Recommended forward RF level
is 0 dBmV.

RF Connection

Fig. 2-3, RF Connection with Ground Block

Ground Surge

Protector

(User Provided)

Alpha requires installing a grounded surge suppressor (Alpha P/N 162-028-10 or equivalent).

See Caution Below

RF Cable

to Headend

2.5 Verifying Transponder Operation

The LED behavior per the table below shows the status of LEDs during transponder
operation:

Communication State

HMS

RDY

Tx

Rx

Transponder Initializing

OFF and ON

OFF and ON

OFF and ON

OFF and ON

Searching for DOCSIS Downstream Channel

OFF

OFF and ON

OFF

OFF and ON

DOCSIS Channel Locked;
Establishing Upstream IP Connectivity

OFF

OFF and ON

OFF and ON

ON

IP Connectivity Established; Registering with CMTS

OFF

OFF and ON

ON

ON

Registration Complete

OFF and ON

OFF and ON

ON

ON