Installation Instructions for Specifi c Power Supplies, continued
3.1
Alpha XM2 Series, continued
3.1.6 Provisioning the Network for the XM2 Series
The transponder must be recognized by the CMTS as a valid device, be able to
obtain an IP address and communicate with the SNMP management server.
Load the transponder’s MAC address into the CMTS.
1.
Compile the two MIBs using a network manager or MIB browser software.
2.
Setup SNMP using two proprietary MIBs fi les.
3.
Set the MIBS points for the XM2 as follows:
4.
For XM2
Oid: 1.3.6.1.4.1.2183.2.3.3.1.2 set to (2) (power supply
selection)
Oid: 1.3.6.1.4.1.2183.2.3.6.5 set to (4) (output voltage
scaling)
Oid: 1.3.6.1.4.1.2183.2.3.6.6 set to (1)for 110V powered
supply or (2) for 220V
Install and confi gure the DOCSIS confi guration fi le. See Section 2.1.9 for a
5.
sample fi le.
Refer to Section 4.0, "Proprietary Management Information Bases (MIBs)" for
detailed information.