Alpha Technologies AlphaNet Series External DOCSIS User Manual
Page 23

23
745-838-B2-001 Rev. A
3.0
Installation Instructions for Specifi c Power Supplies, continued
3.2
Alpha XM Series Power Supply, continued
3.2.4 Provisioning the Network for the XM Series
The transponder must be recognized by the CMTS as a valid device, obtain an IP
address, and communicate with the SNMP management server.
Load the transponder’s MAC address into the CMTS.
1.
Setup SNMP using two proprietary MIBs fi les.
2.
Compile the two MIBs onto a network manager or MIB browser software.
3.
Set the MIBS points for the XM as follows:
4.
Oid: 1.3.6.1.4.1.2183.2.3.3.1.2 set to (3) (power supply
selection)
Oid: 1.3.6.1.4.1.2183.2.3.6.5 set to (4) (output voltage
scaling)
Oid: 1.3.6.1.4.1.2183.2.3.6.6 set to (1)for 110V powered
supply or (2) for 220V (input voltage measurement)
Install and confi gure the DOCSIS confi guration fi le. See Section 2.1.9 for a
5.
sample fi le.
See Section 4.0, Proprietary Management Information Bases (MIBs) for detailed
information.