Alpha Technologies Mini-Mite Ferro Power Supply User Manual

Page 12

Advertising
background image

12

CM003101 Rev. B0

4. Operation

4.2

Service

Part of the unit’s thermal design is heat conduction
from the transformer brackets to the cabinet of the
power supply. A thin coating of silicone grease is
applied to the bracket contact area during
manufacture. Be sure to apply a fresh coat of silicone
grease and tighten all four retaining nuts securely
during reassembly.

Lethal voltages are present within the chassis
when the unit is in operation. For safety, be certain to
unplug the input cord and the output cable connector
before attempting service.

NOTE

CAUTION

Advertising