Alpha Technologies APX Series User Manual

Page 36

Advertising
background image

36

016-030-B0-005, Rev. C

Installation Procedure:

The AMM-C Ammeter is placed in series with the transformer (Tab #4) and output fuse.
Before installing the ammeter, disconnect the black wire connected to the rear-most section
of the fuse holder (the other end of this wire is connected to Tab #4 on the transformer).

Insert the AMM-C partially into the slot on the fuse / meter bracket, making sure that the
0-Amp reading is at the bottom. For shelf mount installations, use slot shown.

Partially place the meter pressure clip so it just catches the meter. Keep the AMM-C free
to easily reach the wire connections. The teeth on the pressure clip should face the rear
of the ammeter.

Connect the wire removed in step 1 to the upper terminal of the AMM-C.

Connect the 8" wire to the rear-most terminal on the fuse holder. Connect the other end
to the lower terminal on the AMM-C.

Fully insert the AMM-C into the slot and slide the pressure clip completely forward until it
contacts the underside of the fuse/meter bracket.

Reconnect the APX to line power and test the AMM-C for proper operation.

1.

2.

3.

4.

5.

6.

AMM-C (Ammeter)

The AMM-C Ammeter displays output current to the load and provides a visual indication of
the load applied to the APX. You can also use the AMM-C to determine if an open or short
circuit condition exists.

The AMM-C options consists of an ammeter, pressure mounting bracket, and an 8"
connecting cable with spade-lug connectors.

2.0 Installation,

continued

2.10 Options,

continued

.

Fig. 2-26, AMM-C Ammeter Kit

Meter Pressure Clip

Ammeter

8" Wire

Remove this wire

from fuse-holder.

Mounting Slot for

Shelf Mount Installations

Mounting Slot for

Ammeter

Install on upper terminal

Fig. 2-27, AMM-C Install Steps