Always verify USM2 configuration especially after upgrading or modifying the XM2 Series 2 Power Supply.

Function Switch SW1 Reference

The following information describes each switch position (1–8) for the DIP switch SW1. SW1 is an eight switch

component used primarily to select analog scaling and digital signal polarity for the USM2 card.

SW1 (1 and 2): Inverter Battery Voltage Scaling Select

SW1, positions 1 and 2 are used together to select the appropriate scaling for the XM2 Series 2 battery
voltage measurement.

SW1 (1) SW1 (2) Battery Scaling
OFF

OFF

0.1VDC/VDC

OFF

ON

0.3VDC/VDC

ON

OFF

0.3VDC/VDC Same as previous setting.

ON

ON

0.5VDC/VDC

SW1 (3): Output Current Scaling

SW1, position 3 is used to select the appropriate scaling for the XM2 Series 2 AC OUTPUT CURRENT#1.

SW1 (3) Output Current #1
OFF

0.4VDC/AAC for Output Current less than 20A.

ON

0.4VDC/AAC for Output Current equal to or greater than 20A.

The switch settings for the Output Current Scaling are for “new” USM2, see Note following SW1 (4) on the next page.