Atec Anritsu_MT8801C User Manual

Page 20

Advertising
background image

Reception measur

ement

20

◆ MX880131A PDC Measurement Software (extracts)

Transmission measur

ement

Reception measur

ement

◆ MX880132A PHS Measurement Software (extracts)

Transmission measur

ement

Reception measur

ement

Frequency/

Frequency range: 10 MHz to 2.2 GHz

modulation

Modulation accuracy: ±(2% of indicated value + 0.5%)

measurement

Amplitude

Input level range: +10 to +40 dBm (average power with burst, MAIN connector)

measurement

Transmitter power accuracy: ±10% (MAIN connector, after calibration by using built-in power meter)

Adjacent channel
power measurement

Measurement range:

Ն

60 dB (50 kHz offset),

Ն

65 dB (100 kHz offset)

Batch measurement

Measurement time:

Յ

1.5 s (amplitude measurement in normal mode; occupied bandwidth and adjacent

functions

channel power measurement on high-speed mode)

Frequency range: 10 MHz to 3 GHz

Signal generator

Level range: –133 to –13 dBm (MAIN connector), –133 to +7 dBm (AUX connector)
Modulation accuracy:

Յ

3%rms

Error rate

Measurement pattern: PN9, PN15

measurement

Number of measurement bits: 10

2

, 10

3

, 2556, 10

4

, 10

5

, 10

6

,

∞

Frequency/

Frequency range: 10 MHz to 2.2 GHz

modulation

Modulation accuracy: ±(2% of indicated value + 0.7%)

measurement

Amplitude

Input level range: +10 to +40 dBm (average power with burst, MAIN connector)

measurement

Transmitter power accuracy: ±10% (MAIN connector, after calibration by using built-in power meter)

Adjacent channel

Measurement range:

Ն

60 dB (600 kHz offset),

Ն

65 dB (900 kHz offset)

power measurement

Batch measurement

Measurement time:

Յ

1.5 s (amplitude measurement in normal mode; occupied bandwidth and adjacent

functions

channel power measurement on high-speed mode)

Frequency range: 10 MHz to 3 GHz

Signal generator

Level range: –133 to –13 dBm (MAIN connector), –133 to +7 dBm (AUX connector)
Modulation accuracy:

Յ

3%rms

Error rate

Measurement pattern: PN9, PN15

measurement

Number of measurement bits: 10

2

, 10

3

, 2556, 10

4

, 10

5

, 10

6

,

∞

◆ MX880118A DECT Measurement Software (extracts)

T

ransmission measur

ement

Frequency/

Frequency: 10 MHz to 2.2 GHz

modulation

RF carrier accuracy: ±250 Hz + reference oscillator accuracy

measurement

Frequency drift measurement accuracy: ±250 Hz
Modulation measurement accuracy: ±10 kHz

Input level range: –5 to +40 dBm (MAIN connector)

Amplitude

Calibration input level range: +15 to +40 dBm (MAIN connector)

measurement

Transmitter power accuracy: ±0.4 dB (+15 to +40 dBm), ±0.7 dB (–5 to +15 dBm)

∗

MAIN connector, after calibration by using built-in power meter

Emission due to modulation:

–8 dBm/160

␮

W at M ±1, –30 dBm/1

␮

W at M ±2, –44 dBm/40 nW at M ±3,

Adjacent channel

–47 dBm/20 nW at M ±4 and M ±5

power measurement

Emission due to transmitter transient:

–6 dBm/250

␮

W at M ±1, –13 dBm/40

␮

W at M ±2, –23 dBm/4

␮

W at M ±3,

–30 dBm/1

␮

W at M ±4 and M ±5

All measurement

Frequency, deviation, frequency drift, Tx power, carrier-off power, template pass/fail, timing, adjacent channel emission

items

Frequency range: 10 MHz to 3 GHz

Signal generator

Level range: –133 to –13 dBm (MAIN connector), –133 to +7 dBm (AUX connector)
Modulation error:

Ϲ

±8% (at 288 kHz deviation, frequency: 10 MHz to 2.2 GHz)

Modes: FER, BER (quick mode), BER (full mode)
Measurement pattern:

Error rate

0000111100001111, 0011001100110011, 0101010101010101, 1010 64

✕

1 64

✕

0 1010,

measurement

pseudorandom (D-2M), ETSI patterns

Number of measurement bits: 1 k to 99000 k

Call processing

Bearer setup, bearer release, hand-over loop back

Advertising