Product construction, Buttons, Overview of functions – Atec AEMC-3710-3730 User Manual

Page 3: Functions & features

Advertising
background image

TECHNICAL ASSISTANCE (800) 343-1391

www.aemc.com

Overview of Functions

8.8.8.8

3,000 count display

Displayed when measuring resistance

mA, A

Displayed when measuring current

100%

Percentage of battery life remaining

Flashing indicates low battery condition

Indicates the auto-off feature is inactive

HOLD

HOLD pushbutton has been pressed

Active beeper function

NOISE Noise in the reading

Probe jaws not closed properly

Alarm set points

MEM

Memory function active

8 8

Memory Recall (MR) and register

Resistance measured is below 1

On/Off

Power ON or power OFF. Activates display
self test at power-up.

( )

Resistance measurement. (Adjusts the alarm
set point and the memory position when in
programming mode.)

A ( )

Current measurement. (Adjusts the alarm
set point and the memory position when in
programming mode.)

AL (Model 3730)

Activate/deactivate the alarm function. Accesses
the value of the alarm setpoint when in
programming mode.

MEM (Model 3730)

Activate the memory function or read the stored
values in MR (Memory Recall). Clears
the memory when in programming mode.

Product Construction

The Models 3710 and 3730 bodies are
built of Lexan

®

or equivalent for rugged

use. The probe heads are encapsu-
lated in a double-walled shell
for extra strength and
reinforced for enhanced
field
reliability.
Overall
construction
and mechanical
design ratings such
as drop test, shock and
vibration, weatherproofing
against water projections
or dust, meet or
exceed IEC-1010 Cat. III
standards. These products
have also been designed to meet UL,
CSA and GS safety approvals, and are CE marked.

The probe head, or jaw, is a key component in the measurement and over-
all product performance.

The large jaw thickness permits use on tight ground conductors on poles
and in manholes. The 1.25" (32 mm) opening accommodates not only
ground rods, but larger ground conductors (up to 1000 MCM) typically
found in telecommunication buildings or railroad applications.

The inner jaw is composed of two independent and individually shielded
magnetic cores permitting measurement without noise interference or
cross talk common to separate probe instruments.

Thorough mechanical design,
including small winglets,
ensures repetitive jaw align-
ment for accuracy and pre-
vents undesirable insertions
into the jaw spring assembly.

The ergonomic body design
permits one-handed opera-
tion. The guard provides addi-
tional strength, and prevents
the hand from slipping or
coming into contact with con-
ductors under test. The LCD
lens cover may be easily
replaced if scratched. The
sealed push-buttons directly
access all test functions and
are easily operated even with
gloved hands.

+

Buttons

MR

Functions & Features

3710 3730

Ohms Range

YES

YES

Amperes (TRMS) Range

YES

YES

Hold Function

YES

YES

Self Test @ Power Up

YES

YES

Auto Off

YES

YES

LCD Battery Life Indicator

YES

YES

LCD Noise Indicator

YES

YES

LCD Open Jaw Indicator

YES

YES

LCD Closed Loop Indicator YES

YES

Multi-Tone Beeper

YES

YES

Alarm Function

YES

Memory (Logging) Function

YES

Advertising