Second harmonic, Intercept point, Residual responses – Atec Agilent-8542E-8546A User Manual

Page 3: Displayed average noise level

Advertising
background image

3

Second Harmonic

Band 1

Band 2

Band 3*

Intercept Point

9 kHz to

20 MHz to

1 to

8542E/8546A

50 MHz

2.9 GHz

6.5 GHz

100 kHz

f

0

1.8 GHz, > 2.9 GHz

Preamp off

122 dBµV

122 dBµV

134 dBµV

Preamp on

110 dBµV

110 dBµV

100 dBµV

1.8 GHz < f

0

2.9 GHz

Preamp off

105 dBµV

Preamp on

105 dBµV

85422E/85462A

(No bands)

f

0

> 200 kHz

Preamp off

134 dBµV

Preamp on

100 dBµV

Amplitude Specifications (continued)

Other Input Related Spurious

–65 dBc (Band 1, Band 2, and Band 3*)

Residual Responses

(0 dB attenuation, 50

input termination, preamp on)

8542E/8546A
< 30 kHz

< –2 dBµV

> 30 kHz

< –10 dBµV

85422E/85462A
9 to 150 kHz

< +2 dBµV

150 kHz to 2.9 (or 6.5 GHz*)

< –8 dBµV

Displayed Average Noise Level

(input terminated, 0 dB attenuation, 50

input termination, 30 Hz IF BW, sample detection

30 Hz averaging BW)

8542E/8546A

30
20
10

0

–10
–20
–30
–40

9

50

100

400

kHz

dB

µ

V

Preamp off

Preamp on

20
10

–20
–30
–40
–50

–10

0

9

100

50

400

kHz

dB

µ

V

Preamp off

Preamp on

f

0

400 kHz

85422E/85462A

f

0

400 kHz

f

0

> 400 kHz

f

0

> 400 kHz

Band 1

Band 2

Band 3*

9 kHz to

20 MHz to

1 to

50 MHz

2.9 GHz

6.5 GHz

–31 dBµV

–31 dBµV

–16 dBµV

–39 dBµV

–39 dBµV

–37 dBµV

Preamp off
Preamp on

Preamp off

–18 dBµV

Preamp on

–39 dBµV

* For 8546A EMI receiver only

Advertising