Continued) – Atec Agilent-6032A User Manual

Page 3

Advertising
background image

54

Supplemental Characteristics
for all model numbers

Remote Sensing: Up to 2 V drop in each
lead. Voltage regulation specification met

with up to 0.5 V drop, but degrades for

greater drops.

Modulation: (analog programming of
output voltage and current)
Input signal: 0 to 5 V or 0 to 4 k Ohms

Size: 6030A–32A, 6035A:
425.5 mm W x 132.6 mm H x 503.7 mm D

(16.75 in x 5.25 in x 19.83 in).

6033A, 6038A:

212.3 mm W x 177.0 mm H x 516.4 mm D

(8.36 in x 6.97 in x 17.87 in).

See page 99 for more details.

Warranty: Three years

Ordering Information

Opt 001 Front panel has only line switch,
line indicator, and OVP adjust
(6030A–33A and 6038A only)

Opt 100 87 to 106 Vac, 48 to 63 Hz
(power supply output is derated to 75%)

Opt 120 104 to 127 Vac, 47 to 63 Hz

Opt 220 191 to 233 Vac, 48 to 63 Hz

Opt 240 209 to 250 Vac, 48 to 63 Hz

Opt 800 Rack-mount Kit for Two
Half-rack Units Side by Side.
Lock link Kit p/n 5061-9694 and
7 in Rack adapter Kit 5063-9215

* Opt 908 Rack-mount Kit for a Single

Half-rack Unit 6033A and 6038A
(with blank filler panel); p/n 5062-3960,
6030A–32A and 6035A; p/n 5062-3977

* Opt 909 Rack-mount Kit with Handles.

For 6030A–32A, 6035A; p/n 5062-3983

Autoranging: 200 W and 1000 W GPIB

(Continued)

Power Products Catalog 2002-2003

For more detailed specifications see the product manual at

www.agilent.com/find/power

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

S p e c i f i c a t i o n s

(at 0

˚

to 55

˚

C unless

otherwise specified)

6030A 6031A 6032A 6033A 6035A 6038A

Supplemental Characteristics

(Non-warranted characteristics determined by design and
useful in applying the product)

Programming resolution Voltage

50 mV

5 mV

15 mV

5 mV

125 mV 1

5 mV

Current

4.25 mA

30 mA

12.5 mA

7.5 mA

1.25 mA

2.5 mA

dc floating voltage

±550 V

±240 V

±240 V

±240 V

±550 V

±240 V

either terminal can be grounded
or floated from chassis ground

ac input current

100 Vac

24 A

24 A

24 A

6 A

24 A

6 A

120 Vac

24 A

24 A

24 A

6.5 A

24 A

6.5 A

220 Vac

15 A

15 A

15 A

3.8 A

15 A

3.8 A

240 Vac

14 A

14 A

14 A

3.6 A

14 A

3.6 A

Weight

Net

16.3 kg

17.2 kg

16.3 kg

9.6 kg

16.3 kg

9.6 kg

(36 lb)

(38 lb)

(36 lb)

(21 lb)

(36 lb)

(21 lb)

Shipping

21.8 kg

22.7 kg

21.8 kg

11.4 kg

21.8 kg

11.4 kg

(48 lb)

(50 lb)

(48 lb)

(25 lb)

(48 lb)

(25 lb)

Opt 0L2 Extra Standard
Documentation Package

Opt 0B3 Service Manual

Opt 0B0 No documentation package

Opt J01 Stabilization for loads up to
10 Henries (not available on 6033A)

A line cord must be specified for 6030A-32A,
6035A. See pages 93-98 for ordering
information.

* Support rails required

Accessories

5080-2148 Serial Link Cable, 2 m (6.6 ft)

1494-0060 Rack Slide Kit

E3663AC Support rails for Agilent rack
cabinets

Advertising
This manual is related to the following products: