Continued) – Atec Agilent-6032A User Manual
Page 3

54
Supplemental Characteristics
for all model numbers
Remote Sensing: Up to 2 V drop in each
lead. Voltage regulation specification met
with up to 0.5 V drop, but degrades for
greater drops.
Modulation: (analog programming of
output voltage and current)
Input signal: 0 to 5 V or 0 to 4 k Ohms
Size: 6030A–32A, 6035A:
425.5 mm W x 132.6 mm H x 503.7 mm D
(16.75 in x 5.25 in x 19.83 in).
6033A, 6038A:
212.3 mm W x 177.0 mm H x 516.4 mm D
(8.36 in x 6.97 in x 17.87 in).
See page 99 for more details.
Warranty: Three years
Ordering Information
Opt 001 Front panel has only line switch,
line indicator, and OVP adjust
(6030A–33A and 6038A only)
Opt 100 87 to 106 Vac, 48 to 63 Hz
(power supply output is derated to 75%)
Opt 120 104 to 127 Vac, 47 to 63 Hz
Opt 220 191 to 233 Vac, 48 to 63 Hz
Opt 240 209 to 250 Vac, 48 to 63 Hz
Opt 800 Rack-mount Kit for Two
Half-rack Units Side by Side.
Lock link Kit p/n 5061-9694 and
7 in Rack adapter Kit 5063-9215
* Opt 908 Rack-mount Kit for a Single
Half-rack Unit 6033A and 6038A
(with blank filler panel); p/n 5062-3960,
6030A–32A and 6035A; p/n 5062-3977
* Opt 909 Rack-mount Kit with Handles.
For 6030A–32A, 6035A; p/n 5062-3983
Autoranging: 200 W and 1000 W GPIB
(Continued)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies
speed and accuracy for test optimization
S p e c i f i c a t i o n s
(at 0
˚
to 55
˚
C unless
otherwise specified)
6030A 6031A 6032A 6033A 6035A 6038A
Supplemental Characteristics
(Non-warranted characteristics determined by design and
useful in applying the product)
Programming resolution Voltage
50 mV
5 mV
15 mV
5 mV
125 mV 1
5 mV
Current
4.25 mA
30 mA
12.5 mA
7.5 mA
1.25 mA
2.5 mA
dc floating voltage
±550 V
±240 V
±240 V
±240 V
±550 V
±240 V
either terminal can be grounded
or floated from chassis ground
ac input current
100 Vac
24 A
24 A
24 A
6 A
24 A
6 A
120 Vac
24 A
24 A
24 A
6.5 A
24 A
6.5 A
220 Vac
15 A
15 A
15 A
3.8 A
15 A
3.8 A
240 Vac
14 A
14 A
14 A
3.6 A
14 A
3.6 A
Weight
Net
16.3 kg
17.2 kg
16.3 kg
9.6 kg
16.3 kg
9.6 kg
(36 lb)
(38 lb)
(36 lb)
(21 lb)
(36 lb)
(21 lb)
Shipping
21.8 kg
22.7 kg
21.8 kg
11.4 kg
21.8 kg
11.4 kg
(48 lb)
(50 lb)
(48 lb)
(25 lb)
(48 lb)
(25 lb)
Opt 0L2 Extra Standard
Documentation Package
Opt 0B3 Service Manual
Opt 0B0 No documentation package
Opt J01 Stabilization for loads up to
10 Henries (not available on 6033A)
A line cord must be specified for 6030A-32A,
6035A. See pages 93-98 for ordering
information.
* Support rails required
Accessories
5080-2148 Serial Link Cable, 2 m (6.6 ft)
1494-0060 Rack Slide Kit
E3663AC Support rails for Agilent rack
cabinets