Supplemental characteristics for all model numbers – Atec Agilent-6621A-6622A User Manual

Page 3

Advertising
background image

3

Agilent models: 6621A, 6622A, 6623A, 6624A, 6627A

Output 2

Output 4

Output 3

Output 1

Top

Terminal Strip Detail

Output 2 & 3

Side

Rear

Output 1 & 4

425.5 mm

16.75"

497.8 mm

19.6"

518.2 mm

20.4"

128 mm

5.04"

-O V +O V -S

-V

+V +S

+S +V -V +S +O V

-O V

12.7 mm

0.5"

132.6 mm

5.2"

Screw Size:
M3.5 x 0.6

Supplemental characteristics
for all model numbers

DC floating voltage: Output terminals
can be floated up to ± 240 VDC from
chassis ground

Remote sensing: Up to 1 V drop per
load lead. The drop in the load leads
subtracts from the voltage available
for the load.

Command processing time:
7 ms typical with front-panel display
disabled

Output programming: Current sink
limits are fixed approximately 10%
higher than source limits for a given
operating voltage above 2.5 V.

Input power: 550 W max., 720 VA max.

GPIB interface capabilities:
SH1, AH1, T6, L4, SR1, RL1, PP1, DC1,
DT0

Software driver: VXIplug&play

Regulatory compliance: Listed to
UL1244; conforms to IEC 61010-1;
carries the CE mark.

Size:
425.5 mm W x 132.6 mm H x 497.8 mm
D (16.75 in x 5.22 in x 19.6 in)

Weight: Net, 17.4 kg (38 lb); shipping,
22.7 kg (50 lb)

Warranty: One year

Advertising