General specifications – Atec Chroma-62000H Series User Manual

Page 7

Advertising
background image

Programming & Measurement Resolution
Voltage (Front Panel )

10 mV

Current (Front Panel)

10 mA

Voltage (Digital Interface)

0.002% of Vmax

Current (Digital Interface)

0.002% of Imax

Voltage (Analog Interface )

0.04% of Vmax

Current (Analog Interface )

0.04% of Imax

Remote Interface
Analog programming

Standard

USB

Standard

RS232

Standard

RS485

Standard

GPIB

Optional

Ethernet

Optional

System bus(CAN)

Standard for master/slave control

Programming Accuracy
Voltage (Front Panel and Digital Interface )

0.1% of Vmax

Current (Front Panel and Digital Interface )

0.3% of Imax

Voltage (Analog Interface)

0.2% of Vmax

Current (Analog Interface)

0.3% of Imax

GPIB Command Response Time
Vout setting

GPIB send command to DC source receiver <20ms

Measure V&I

Under GPIB command using Measure <25ms

Analog Interface (I/O)
Voltage and Current Programming inputs (I/P)

0-10Vdc / 0-5Vdc / 0-5k ohm / 4-20 mA of F.S.

Voltage and Current monitor output (O/P)

0-10Vdc / 0-5Vdc / 4-20mA of F.S.

External ON/OFF (I/P)

TTL:Active Low or High(Selective)

DC_ON Signal (O/P)

Level by user define. ( Time delay = 1 ms at voltage slew rate of 10V/ms.)

CV or CC mode Indicator (O/P)

TTL Level High=CV mode ; TTL Level Low= CC mode

OTP Indicator (O/P)

TTL: Active Low

System Fault indicator(O/P)

TTL: Active Low

Auxiliary power supply(O/P)

Nominal supply voltage : 12Vdc / Maximum current sink capability: 10mA

Safety interlock(I/P)

Time accuracy: <100ms

Remote inhibit(I/P)

TTL: Active Low

Series & Parallel Operation

*1

Master / Slave control via CAN for 10 units up to 150KW. (Series: two units / Parallel: ten units )

Auto Sequencing(List Mode)
Number of program

10

Number of sequence

100

Dwell time Range

5ms - 15000S

Trig. Source

Manual / Auto / External

Auto Sequencing (Step Mode)
Start voltage

0 to Full scale

End voltage

0 to Full scale

Run time

10ms - 99hours

Input Specification

AC input voltage 3phase , 3 wire + ground

208/220 Vac(operating range 187 -242 Vac) *2

380/400 Vac(operating range 342 - 440 Vac)

440/480 Vac(operating range 396 - 528 Vac) *2

AC frequency range

47-63 Hz

Max Current(each phase)

208/220 Vac

5KW Model:39A

10KW Model:66A

15KW Model:91A

380/400 Vac

5KW Model:22A

10KW Model:37A

15KW Model:50A

440/480 Vac

5KW Model:19A

10KW Model:32A

15KW Model:44A

General Specification

Maximum Remote Sense Line Drop Compensation

<100V model: 5% of full scale voltage per line(10% total)

>100V model :2% of full scale voltage per line (4% total)

Operating Temperature Rage

0°C ~ 50°C

Storage Temperature Rage

-40°C ~ +85°C

Dimension (HxWxD)

132.8 x 428 x 610 mm / 5.23 x 16.85 x 24.02 inch

Weight

5KW Model : Approx. 23 kg / 50.66 lbs

10KW Model : Approx. 29 kg / 63.88 lbs

15KW Model : Approx. 35 kg / 77.09 lbs

gENEral SPEciFicatiONS

Note*1

: To parallel more than 5 units, please contact factory.

Note*2

: Call for availability.

All specifications are subject to change without notice. Please visit our website for the most up to date specifications.

Advertising